SRC PORT COMP
Type of comparison that is performed. Default is NONE.
= means ports equal to
not = means port not equal to
> means port greater than
< means port less than
None - means the source port is not compared
DEST PORT
IP destination port number used for comparison. Value is in decimal format. Range: 0 TO 65535.
Default is
0.
DEST PORT COMP
Type of comparison that is performed. Default is NONE.
= means ports equal to
not = means port not equal to
> means port greater than
< means port less than
None - means the source port is not compared
PROTO PORT
Protocol used for comparison. Value is in decimal format. Range: 0 TO 255. Default is 0.
PROTO PORT COMP
Type of comparison that is performed. Default is NONE.
= means ports equal to
not = means port not equal to
> means port greater than
< means port less than
None - means the source port is not compared
TCP ESTAB
Ye s - only when TCP established
No - only when TCP not established
Ignore - ignore TCP flags (default)