Upgrade From A.03 to A.03.9X (Transition Build) to A.04
1. Upgrade the firmware from A.03 to A.03.9X (Transition Build) firmware. See DLP-007 or DLP-008 for
instructions on how to perform this upgrade.
2. Once the upgrade to A.03.9X is complete, immediately upgrade the unit to A.04. See
DLP-007 or DLP-008 for instructions on how to perform this upgrade.
Upgrade From A.03 to A.04 Directly
1. Upgrade the firmware from A.03 to A.04 firmware. See DLP-007 or DLP-008 for instructions on how to
perform this upgrade.
2. The unit must then be factory defaulted: by one of the following methods:
•Select S
YSTEM UTILITY>TERMINAL MODE. At the > prompt, type fac. You will then see “Restore
Factory Defaults and Reset Unit? (press 'y').” Press the y key to confirm default. The unit will
then automatically reset.
• If connected to the CRAFT port, power reset the unit and then restore power to the unit while
holding down the F key. You will then be prompted to confirm the factory default.
3. Reconfigure the unit for the specific application.
Follow-up Procedures
Once this procedure is complete, return to the procedure which referred you to this DLP and continue with
the tasks indicated there.
Perform Steps Below in the Order Listed
Upgrading from A.03 to A.03.9X (Transition Build) to A.04 will save the unit's
configuration.
Upgrading from A.03 to A.04 directly (or from A.04 to A.03 directly) will erase the unit's
configuration.