GENERAL INFORMATION
1-4
Performance data
Specifications guaranteed under the following conditions:
20 minutes warm-up time at ambient temperature
specified environmental conditions met
calibration cycles adhered to
total calibration performed
specifications apply for the default phase noise ‘optimized > 10 kHz’ unless otherwise
stated.
CARRIER FREQUENCY
Range: 250 kHz to 2 GHz (3412)
250 kHz to 3 GHz (3413)
250 kHz to 4 GHz (3414)
250 kHz to 6 GHz (3416)
Resolution: 1 Hz
Accuracy: Equal to the frequency standard accuracy
Phase incrementing:
The carrier phase can be advanced or retarded in steps of 0.036
° using the rotary
control.
FREQUENCY SETTING TIME (NON
LIST MODE)
after receipt of GPIB interface
delimiter (terminator), 23°C ±5°C
Phase noise mode optimized
> 10 kHz:
< 5.5 ms, typically 4 ms ≤ 375 MHz, to be within ≤ 200 Hz
> 375 MHz, to be within ≤ 0.1 ppm
Phase noise mode optimized
< 10 kHz:
< 3 ms, typically 2.5 ms ≤ 375 MHz, to be within ≤ 200 Hz
< 2.5 ms, typically 2 ms > 375 MHz, to be within ≤ 0.1 ppm
FREQUENCY SETTING TIME
(OPTION 10 LIST MODE)
after external trigger in list mode,
23°C ±5°C
Phase noise mode optimized
> 10 kHz:
< 4 ms, typically 3 ms ≤ 375 MHz, to be within < 200 Hz
> 375 MHz, to be within < 0.1 ppm
Phase noise mode optimized
< 10 kHz:
< 600 µs, typically 500 µs ≤ 375 MHz, to be within < 200 Hz
< 500 µs, typically 450 µs > 375 MHz, to be within < 0.1 ppm