REMOTE OPERATION POWER COMMANDS
4-154
[SOURce]:POWer:QRFNull
Description: Optimizes RF level accuracy performance.
Parameters: none
Valid values: none
[SOURce]:POWer:SWEep:DWELl
Description: Sets the time per sweep step for carrier level.
Parameters: <numeric_value>
Valid values: <NRf>(s) | MAXimum | MINimum
*RST sets: 50 ms
[SOURce]:POWer:SWEep:DWELl?
Description: Queries the time per sweep step for carrier level.
Parameters: None
Response: <NR2>
Returned values: Time per sweep step in s
[SOURce]:POWer:SWEep:MANual
Description: Sets the output power sweep level.
Parameters: <numeric_value>
Valid values: <NRf>(dB) | MAXimum | MINimum | UP | DOWN
Set by value, to maximum or minimum, or stepping up or down.
<level> is in units set by :UNIT:POW or :UNIT:VTYP on page 4-172.
[SOURce]:POWer:SWEep:MANual?
Description: Queries the value of the output power sweep level.
Parameters: None
Response: <NR2>
Returned values: Power level, in the units set on page 4-172