Chapter 6
Programming Via Configuration Bar Code Symbols
6–19
Enter
XON/XOFF
Exit
XON/XOFF Pacing
Whenever this pacing protocol is enabled, the decoder will stop transmission of
data to the host whenever it receives an XOFF character. Transmission will
resume after reception of an XON character. When pacing is disabled, the
decoder will ignore these characters.
*Default is
XON/XOFF Disabled
.
Enter
Single Read Mode
Exit
Single Read Mode
In this mode, a single bar code symbol may be read only
after an
Enable Next Read
command has been received by
the decoder. This allows the software in the host computer
to control when bar code data is entered into the system.
When single read mode is enabled, bar code symbols
will not be decoded until the
Enable Next Read
escape
sequence is sent from the host to the decoder.
The
Enable Next Read
command can be found on page
5–32
*Default is Single
Read Mode Disabled
.
Note: These symbols should only be used in conjunction
with host programming.
Display Terminal Port
Scan these symbols to enable and disable bar code data from being
transmitted to the display terminal in case the host echoes data to the
terminal.
For More information on the Display Terminal port, refer to
Chapter 3, Host
Computers and Display Terminals.
*Default is Terminal Port enabled.
Enter
Enable/Disable
Terminal Port
Exit