Table of Contentsvi
Publication
1747-6.2
Recommendations for Wiring I/O Devices
7–5
. . . . . . . . . . . . . . . . . .
Features
of an I/O Module
7–6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wiring Y
our I/O Modules
7–7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Octal
Label Kit Installation
7–8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Applying
the Octal Filter Label
7–8
. . . . . . . . . . . . . . . . . . . . . . . .
Applying
the Octal Door Label
7–8
. . . . . . . . . . . . . . . . . . . . . . . . .
Octal
Kit and I/O Module Information
7–9
. . . . . . . . . . . . . . . . . . . .
Using
the Removable T
erminal Block (RTB)
7–10
. . . . . . . . . . . . . . . . .
Removing
the R
TB
7–10
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing
the R
TB
7–1
1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 8
Procedures
for Starting Up the Control System
8–1
. . . . . . . . . . . . . .
Inspect Y
our Installation
8–2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Disconnect Motion-causing Devices
8–2
. . . . . . . . . . . . . . . . . . . . . .
Initialize
and T
est Your Processor
8–3
. . . . . . . . . . . . . . . . . . . . . . . .
Test Y
our Inputs
8–5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input
T
roubleshooting Steps
8–6
. . . . . . . . . . . . . . . . . . . . . . . . . .
Test Y
our Outputs
8–7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output
T
roubleshooting Steps
8–8
. . . . . . . . . . . . . . . . . . . . . . . . .
Enter
and T
est Your Program
8–9
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Observe
Control Motion
8–1
1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Conduct a Dry Run
8–12
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 9
Handling
and Storing Battery
, Catalog Number 1747-BA
9–1
. . . . . . . .
Handling
9–1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storing
9–1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transporting
9–2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing
and Replacing the Battery of the
SLC 5/01 or SLC 5/02 Processor
9–4
. . . . . . . . . . . . . . . . . . . . . .
Replacing Y
our SLC 5/03, SLC 5/04, or SLC 5/05 Battery
9–5
. . . . . . .
Replacing
Retainer Clips on an I/O Module
9–6
. . . . . . . . . . . . . . . . .
Removing
Damaged Retainer Clips
9–6
. . . . . . . . . . . . . . . . . . . . .
Installing
New Retainer Clips
9–7
. . . . . . . . . . . . . . . . . . . . . . . . .
Replacing
a Fuse on the Power Supply
9–8
. . . . . . . . . . . . . . . . . . . .
Chapter 10
Calling Allen-Bradley for Assistance
10–1
. . . . . . . . . . . . . . . . . . . . . .
Tips
for T
roubleshooting Y
our Control System
10–2
. . . . . . . . . . . . . . .
Removing Power
10–2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Replacing Fuses
10–3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Program
Alteration
10–3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting
the SLC 5/01 and SLC 5/02 Processors
10–3
. . . . . . .
Identifying
SLC 5/01 and SLC 5/02 Processor Errors
10–4
. . . . . . . .
Starting Up Your Control
System
Maintaining Your Control
System
Troubleshooting
AB PLCs

Table of Contents

Other manuals for Allen-Bradley SLC 500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley SLC 500 and is the answer not in the manual?

Allen-Bradley SLC 500 Specifications

General IconGeneral
Programming SoftwareRSLogix 500
Communication PortsRS-232, DH-485, DH+
Power Supply120/240V AC or 24V DC
Programming LanguagesLadder Logic
Operating Temperature0°C to 60°C (32°F to 140°F)
Relative Humidity5% to 95% (non-condensing)
Memory4K to 64K words (depending on the processor)