Loading...
IV-49
Entry procedure
(Inserting interrupt station (10 mm × 2 pieces) between
stations 1 and 2)
1 Enter with the
numeric keys the
number for the station
before which to insert
the interrupt station.
(In this example, enter
“2”, and press the
ENT key.)
The cutting data of the station 2 are displayed.
2 Press the MENU key
several times to
display the F1 (ST
interrupt) key.
3 Press the F1 (ST
interrupt) key.
The L, P, and C fields
are all reset to “0”.
4 Press the ENT key to
move the cursor to the
L field.
5 Enter the cutoff length
with the numeric keys.
(In this example, enter
“1” and “0”, and press
the ENT key.)
The cursor moves to
the P field.
6 Enter the quantity of
pieces to be cut with
the numeric keys.
(In this example, enter
“2”, and press the
ENT key.)
This completes the
setting of the interrupt
station.

Table of Contents