Rewiring hydraulic pump motor
If the hydraulic pump motor runs in the reverse direction, rewire it as
described below.
1 Turn the machine circuit breaker switch to OFF.
The POWER light goes out.
2 Turn off the shop circuit breaker switch.
3 Open the door of the electrical enclosure.
4 Interchange the power cable conductors connected to the L1 (R)
and L3 (T) terminals of the machine circuit breaker.
5 Close the door of the electrical enclosure.
6 Repeat the electrical connection checking procedure to reconfirm
that the sawhead rises when the BLADE UP button is held
pressed.
INSTALLING FIRE CONTROL DEVICES
Install a fire extinguisher or other fire control device in the shop to
provide against fires.