IV-51
Entry procedure
(Inserting interrupt station (10 mm × 2 pieces) before station
1 while head end of work is being trimmed)
1 Enter with the
numeric keys the
number for the station
to be executed after
trimming (or the first
station of automatic
operation). (In this
example, enter “1”,
and press the ENT
key.)
The cutting data of the station 1 are displayed.
2 Press the MENU key
several times to
display the F1 (ST
interrupt) key.
3 Press the F1 (ST
interrupt) key.
The L, P, and C fields
are all reset to “0”.
4 Press the ENT key to
move the cursor to the
L field.
5 Enter the cutoff length
with the numeric keys.
(In this example, enter
“1” and “0”, and press
the ENT key.)
The cursor moves to
the P field.
6 Enter the quantity of
pieces to be cut with
the numeric keys.
(In this example, enter
“2”, and press the
ENT key.)
This completes the
setting of the interrupt
station.

Table of Contents