V-9
Alarm code Cause Remedy Remarks
Front vise
solenoid
valve is
faulty.
Clear alarm, and manually
check vise open and close
operation.
E-110
FRONT VISE
CLOSE light
does not
come on
within
predetermined
time after
output of front
vise close
signal.
Front vise
pressure
switch is
faulty.
Clear alarm.
Hydraulic pump
motor stops.
Rear vise
solenoid
valve is
faulty.
Clear alarm, and manually
check vise open and close
operation.
Hydraulic pump
motor stops.
E-111 REAR VISE
CLOSE light
does not
come on
within
predetermined
time after
output of rear
vise close
signal.
Rear vise
pressure
switch is
faulty.
Clear alarm.
Saw blade was broken during
operation.
E-112
Saw blade breakage
detection limit switch is faulty.
See “E-001”. Hydraulic pump
motor stops.
Saw blade
slipped.
Check saw blade tension,
clear alarm, and reduce
cutting rate to decrease load.
E-113 Motion
detector
actuated
during
operation.
Motion
detector is
faulty.
Clear alarm.
Hydraulic pump
motor stops.
E-114
During automatic operation,
backward movement amount
of rear vise was different from
its return amount.
Clear alarm, and remove
obstacle near rear vise
forward limit.
Hydraulic pump
motor stops.
E-115 Rear vise moved during
temporary stop of automatic
operation.
Clear alarm. Saw blade stops
running.