Y.1731 protocol setupY.1731 protocol setup
Selecting the Y.1731Y.1731 protocol will display the screen shown below.
The screen contains two views: the default Setup view and the Discovery view.
Use the SetupSetup and DiscoveryDiscovery buttons at the bottom of the screen to switch
between the two views.
The Setup view is described below. The Discovery view is described in a
separate section.
General parametersGeneral parameters
StateState
Allows you to set the state of the protocol to either OnOn or OffOff. Note that when
StateState is set to OnOn, the other general parameters are disabled, but the tabs and
their contents are enabled.
MEP IDMEP ID
Allows you to specify the Local Maintenance Point ID, which will identify the
unit in the MEG (Maintenance Entity Group).
MEG IDMEG ID
Allows you to identify the MEG (MEG End Point) to which the MEP belongs.
MEG levelMEG level
Use the drop-down menu to specify the MEG level at which the MEP exists.
CCM tabCCM tab
The CCMCCM tab contains the Continuity Check Message parameter:
CCM intervalCCM interval
Use the drop-down menu to specify the frequency at which CCMs are
transmitted and expected to be received.
LBM tabLBM tab
The LBMLBM tab contains the Loopback Message parameters:
Ethernet ApplicationsEthernet Applications