EasyManua.ls Logo

Anritsu MT1040A - Page 517

Anritsu MT1040A
684 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Real-Time Control Data :
RTC IDRTC ID
An identifier of a series of Real-Time Control Data
messages.
SEC IDSEC ID
An identifier of each message in a series of
messages.
Remote Memory Access :
Remote MemoryRemote Memory
Access IDAccess ID
The Remote Memory Access ID is used by the sender
of the request when the response is received to
distinguish between different accesses.
Read/WriteRead/Write
0: Read
1: Write
2: Write_No_Resp
Other: Reserved
Req/RecpReq/Recp
0: Request
1: Response
2: Failure
Other: Reserved
Element IDElement ID
Element ID is used for instance to point out a specific
instance of a generic hardware function.
AddressAddress Enter a memory address to read or write.
LengthLength
2-byte Length field contains the actual number of
bytes that were either written or read.
One-way Delay Measurement :
Measurement IDMeasurement ID
The Measurement ID is a 1-byte value used by the
sender of the request when the response is received
to distinguish between different measurements.
Action TypeAction Type Select an Action Type of the message.
TimeStampTimeStamp
A time stamp data which information is specified by
Action Type.
Compensation ValueCompensation Value
When Action Type is set to 0x00 (Request), 0x02
(Response) or 0x05 (Follow_Up) in the message, this
field will contain the ‘Compensation Value’ which is
the compensation time measured in nanoseconds
and multiplied by 2
16
and follows the format for the
correctionField in the common message header
specified in IEEE 1588-2008 Clause 13.3 [13].
Remote Reset :
Reset IDReset ID An identifier of a Remote Reset message.
Reset Code OpReset Code Op
1: Remote reset request
2: Remote reset response
Other: Reserved
eCPRI/RoE BERTeCPRI/RoE BERT