5. Lightly moisten a swab with distilled water. Then squeeze any excess water from the swab.
Wipe the ink cartridge copper contacts with the swab. Wipe the contacts until no ink residue or
dust appears on a clean swab.
Caution: Do not touch the ink cartridge nozzles. Touching the ink nozzles will result in clogs,
ink failure, and bad electrical connections.
6. Hold the ink cartridge so that the copper strip is on the bottom and facing the printer. Slide the
ink cartridge into the cradle as shown.
Tilt the end of the cartridge facing you downward as you insert it. When the cartridge has
reached the back of the cradle, tilt it back upward to its normal position until it clips into the
cradle.
Note: If the ink cartridge slides back toward you, it is not seated properly. Lift the ink cartridge
and press it into the cradle. When installed properly, the ink cartridge will be held in place and
it will not freely move in any direction.
7. Close the front lid. The maintenance tray under the ink cartridge will move forward.