Page 106 2000-1252-01 Released Rev. C
VersaPort 2200 Technical Manual
Chapter 4: Service
CSP2 – Pod Door Lock Motor Replacement
a
_____d. From the Manual menu select F6 (DC MOTOR). Use the arrow keys to
select Unlock Port and press Enter.
_____20. Place a Pod on the port plate and test the lock/unlock sequence following ISIM
commands in Step 14. If door locks properly, proceed. If ISIM errors are
encountered, repeat necessary adjustments.
_____21. Ensure pod door is in Unlock position. Remove Pod from the VersaPort.
Remove PC null modem cable connection. Remove 24vdc power.
Post-Service
_____1. If necessary, return the VersaPort to the Process Tool.
_____2. Reinstall the minienvironment shield.
_____3. The procedure is complete when the VersaPort has been remounted to the
Process Tool—with the minienvironment reinstalled—and has been
Autocycled ten times.