Operation
F-FEM-CON — Users Guide
4.3.2.3
Analog Outputs, General
Quantity Typ. Max. Unit Remark
State during and after
power-up
0
0
V
mA
nominal zero value
Voltage difference between
two channels or between
channel and case or channel
and DGND
60 V
Coupling capacity 13
(7.5)
nF
nF
channel to case
(channel to channel)
External voltage applied at the
outputs
30 V no persistent damage
Tab. 8
NOTICE
All specifications are for an ambient temperature between 0 and 60 °C and a
supply voltage of 24 V +
20 % unless otherwise noted.