Operation
76
F-FEM-CON — Users Guide
4.7.4
Specifications
4.7.4.1
Timing Values
Positive and negative frequencies can be generated. Interpretation:
The output of a positive frequency corresponds to a right-hand rotation. Track A
leads with respect to track B. If the frequency turns negative, this indicates that
the direction of rotation is reversed - track A will lag with respect to track B
(left-hand rotation!)
Quantity Min. Max. Unit Remark
Time resolution 25
20 *)
ns
ns
1 LSB
Frequency resolution 75
93 *)
mHz 1 LSB
Number of teeth Z
n
2 65535 Teeth
Duty Cycle DC 0 100 %
Output frequency
f
AB
(on Track A, Track B) 1000 kHz S.Type: Simulate ABZ
f
Out
(on Single Track Z) 1000
300
kHz
kHz
S.Type: Frequency
S.Type: PWM
Absolute frequency error +
25 ppm Caused by quartz
Update rate 1 1000 Hz For new value, parameterizable
Signalsplitter delay times Signalsplitter signal types
Counter Input to
Frequency Output
460 540 ns SiSp Counter 1,2
Direct Z or Direct ABZ
Counter Input to
Frequency Output
T
in
+
T
PAM
+ 1
T
in
+
2*T
PAM
+ 1
ms SiSp Counter 1,2
T
in
= period of
Counter frequency at input
T
PAM
= parameterized Counter
Update periode
Tab. 15
*) valid for F-FEM-CON Advanced