3. Physical installation
Ensure good condition of the lamp house blower. Keep the blower inlet clean for unrestricted air flow.
To en sure maximum lamp life, operate the lamp house b lower and the exhaust system for at least ten minutes
after extinguishing the lam p.
Optional electrical connection of the fan to the projector
The ex haust fan may electrically be connected w ith the projector. When that is done, the blower starts working when the lamp is
switched on and stops working after the cool period is completed.
The pow er socket is located next to exhaust output and may only b e used to connect the external exhaus
t fan. No connection with
other device s is allowed.
The exhaust outlet delivers maximu m 3A, 200-240V at 50-60Hz.
The external fan power cor d s hall be not less than 0.75 m m ² or AWG 18.
Image 3-6
Fan power connection
22 R59770495 DP2K-23B 30/04/2010