12. Convergence
12.3 C onvergence c ontrols
Denitions-Abbreviations
X: H orizontal d irection on the screen, with or igin in the centre of the screen an d + to the right
Y: Vertical direction on the screen, with origin in the centre of the screen and + to the top
Z rotation: Tilting of the X and Y ax es in their plane: + is clockwise rotation
[1] ; [2 ] ; [3] ; [4] ; [5] ; [6] : these are the 6 adjustments av ailable as they appear on the standard convergence adjustment
screen.
Convergence controls, location
1
2
3
4
5
6
Image 12-5
Convergence knobs
1 Red channel, knob num ber 1
2 Red channel, knob num ber 2
3 Red channel, knob num ber 3
4 Green channel, knob number 4
5 Green channel, knob number 5
6 Green channel, knob number 6
Convergence Test pattern
For the manual correction of the D MD conv
ergence, a typical convergence test pattern is generated.
R59770495 DP2K-23B 30/04/2010
117

Table of Contents

Other manuals for Barco DP2K-23B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Barco DP2K-23B and is the answer not in the manual?

Barco DP2K-23B Specifications

General IconGeneral
Contrast ratio (typical)2000:1
Projector native resolution2K (2048x1080)
Ethernet LANYes
Ethernet LAN (RJ-45) ports3
AC input voltage200 - 240 V
Lamp power4000 W
Weight and Dimensions IconWeight and Dimensions
Depth754 mm
Width604 mm
Height1129 mm
Weight133000 g

Related product manuals