4. Lamp & lamp house
4.6 Resetting the lamp parameters
CAUTION: The “ LAMP INFO” parameters MUST be updated after each installation of an xenon lamp inside
the Lam p House. Neglecting this update will result in poor performance and short life time of the xenon lamp.
How to reset the lamp parameters?
1. Start up the projector but do not ignite the lam p.
2. Go via the Communicator touch pan el to the menu “Installation”>“Lamp”>“Lamp information”.
3. W hile the Lam p information window is displaye d, tap on Reset (1).
A reset message is displayed (2).
4. Tap on Select (3) to display a list of pos sible article numbers (4). S elect a article number (5) and tap OK (6).
The s oftware w ill validate the selected article numbe r (7).
5. Fill out the serial number of the lamp (8).
6. C lick R eset (9).
Image 4-24
Reset lamp info
CAUTION: For more information about using the Communicator Touch Panel consult the user ’s guide of the
Communicator Touch Panel.
42 R59770495 DP2K-23B 30/04/2010