B-30 DGC-2020 Modbus Communication 9400200990 Rev I
Holding
Register
Parameter Range
Read/Write
Supported
Data
Format
Units
44564 Low Oil Press. Pre-Alarm Enable 0-1 R W
0 = Disable
1 = Enable
44566
Low Oil Press. Pre-Alarm
Threshold
3-150 R W psi in increments of 1
44568
Metric Low Oil Press. Pre-Alarm
Threshold
25-1030 R W kPa in increments of 1
44570
Engine Overload 1 Pre-Alarm
Enable
0-1 R W
0 = Disable
1 = Enable
44572
Engine Overload 1 Pre-Alarm
Threshold
95-145 R W % in increments of 1
44574
ECU Comms Fail Pre-Alarm
Enable
0-1 R W
0 = Disable
1 = Enable
44576 Active DTC Pre-Alarm Enable 0-1 R W
0 = Disable
1 = Enable
44578
Maintenance Interval Pre-Alarm
Enable
0-1 R W
0 = Disable
1 = Enable
44580
Maintenance Interval Pre-Alarm
Threshold
0-5000 R W Hours in increments of 1
44582 Speed Sender Fail Activation Delay 0-300 R W Seconds in increments of 1
44584
ECU Low Coolant Level Alarm
Enable
0-1 R W
0 = Disable
1 = Enable
44586
ECU Low Coolant Level Alarm
Threshold
0-100 R W % in increments of 1
44588
ECU Low Coolant Level Pre-Alarm
Enable
0-1 R W
0 = Disable
1 = Enable
44590
ECU Low Coolant Level Pre-Alarm
Threshold
0-100 R W % in increments of 1
44594
Engine Overload 1 Pre-Alarm
3 Phase Hysteresis
1-10 R W % in increments of 1
44596
Engine Overload 1 Pre-Alarm
1 Phase Threshold
95-140 R W % in increments of 1
44598
Engine Overload 1 Pre-Alarm
1 Phase Hysteresis
1-10 R W % in increments of 1
44600
Engine Overload 1 Pre-Alarm
1 Phase Low Line Scale Factor
0-3 R W Increments of 0.001
44602
Engine Overload 2 Pre-Alarm
Enable
0-1 R W
0 = Disable
1 = Enable
44604
Engine Overload 2 Pre-Alarm
3 Phase Threshold
95-140 R W % in increments of 1
44606
Engine Overload 2 Pre-Alarm
3 Phase Hysteresis
1-10 R W % in increments of 1
44608
Engine Overload 2 Pre-Alarm
1 Phase Threshold
95-140 R W % in increments of 1
44610
Engine Overload 2 Pre-Alarm
1 Phase Hysteresis
1-10 R W % in increments of 1
44612
Engine Overload 2 Pre-Alarm
1 Phase Low Line Scale Factor
0-3 R W Increments of 0.001
44614
Engine Overload 3 Pre-Alarm
Enable
0-1 R W
0 = Disable
1 = Enable
44616
Engine Overload 3 Pre-Alarm
3 Phase Threshold
95-140 R W % in increments of 1
44618
Engine Overload 3 Pre-Alarm
3 Phase Hysteresis
1-10 R W % in increments of 1
44620
Engine Overload 3 Pre-Alarm
1 Phase Threshold
95-140 R W % in increments of 1
44622
Engine Overload 3 Pre-Alarm
1 Phase Hysteresis
1-10 R W % in increments of 1
44624
Engine Overload 3 Pre-Alarm
1 Phase Low Line Scale Factor
0-3 R W Increments of 0.001
44626
LSM Comm Failure Pre-alarm
Enable
0-1 R W
0 = Disable
1 = Enable
44628
Intergenset Comm Failure Pre-
alarm Enable
0-1 R W
0 = Disable
1 = Enable
www . ElectricalPartManuals . com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Basler DGC-2020 and is the answer not in the manual?

Basler DGC-2020 Specifications

General IconGeneral
BrandBasler
ModelDGC-2020
CategoryController
LanguageEnglish

Related product manuals