SECTION 6 INSTALLATION
TABLE OF CONTENTS
SECTION 6 INSTALLATION .................................................................................................................. 6-1
GENERAL.............................................................................................................................................. 6-1
PRODUCT REGISTRATION ................................................................................................................. 6-1
HARDWARE.......................................................................................................................................... 6-1
MOUNTING............................................................................................................................................ 6-1
CONNECTIONS .................................................................................................................................... 6-3
Terminations....................................................................................................................................... 6-3
Connections for Typical Applications ................................................................................................. 6-7
Connections for Volvo Penta EDC III Applications........................................................................... 6-12
Connections with LSM-2020 and CEM-2020................................................................................... 6-17
INSTALLATION FOR CE SYSTEMS...................................................................................................6-17
INSTALLATION IN A SALT FOG ENVIRONMENT............................................................................. 6-17
Figures
Figure 6-1. Panel Cutting and Drilling
Dimensions.................................................................................... 6-1
Figure 6-2. Overall Dimensions................................................................................................................. 6-2
Figure 6-3. 3-Phase Wye Connections for Typical Applications ............................................................... 6-8
Figure 6-4. 3-Phase Delta Connections for Typical Applications.............................................................. 6-9
Figure 6-5. Single-Phase A-B Connections for Typical Applications ...................................................... 6-10
Figure 6-6. Single-Phase A-C Connections for Typical Applications ...................................................... 6-11
Figure 6-7. 3-Phase Wye Connections for Volvo Penta EDC III Applications ........................................ 6-13
Figure 6-8. 3-Phase Delta Connections for Volvo Penta EDC III Applications ....................................... 6-14
Figure 6-9. Single-Phase A-B Connections for Volvo Penta EDC III Applications.................................. 6-15
Figure 6-10. Single-Phase A-C Connections for Volvo Penta EDC III Applications ............................... 6-16
Figure 6-11. DGC-2020, LSM-2020, CEM-2020 CANBus Connections................................................. 6-17
Tables
Table 6-1. Operating Power Terminals
..................................................................................................... 6-3
Table 6-2. Generator Current Sensing Terminals ..................................................................................... 6-4
Table 6-3. Generator Voltage Sensing Terminals..................................................................................... 6-4
Table 6-4. Bus Voltage Sensing Terminals............................................................................................... 6-4
Table 6-5. Sender Input Terminals............................................................................................................ 6-5
Table 6-6. Magnetic Pickup Input Terminals............................................................................................. 6-5
Table 6-7. Contact Sensing Inputs............................................................................................................ 6-5
Table 6-8. Programmable Output Contact Terminals................................................................................ 6-6
Table 6-9. RS-485 Communication Port Terminals................................................................................... 6-6
Table 6-10. CAN Interface Terminals........................................................................................................ 6-7
Table 6-11. RDP-110 Interface Terminals................................................................................................. 6-7