9400200990 Rev I DGC-2020 Functional Description 3-11
Event String Event Description
Event
Type
AUTO_RESTART_FAIL_A Automatic Restart Fail Alarm
AUTO_RESTART_IN_PROGRESS Automatic Restart in Progress Status
BATT_CHRG_FAIL_A Battery Charger Fail Alarm
BATT_CHRG_FAIL_P Battery Charger Fail Pre-Alarm
BATT_OVERVOLT_P Battery Overvoltage Pre-Alarm
BATTLE OVERRIDE Battle Override Status
CEM_COMM_FAIL_P CEM-2020 Communications Failure Pre-Alarm
CONFIG_ELEMENT_N_A (where N is
a number in the range of 1 to 8)
Configurable Element N (where N is a number in
the range of 1 to 8)
Alarm
CONFIG_ELEMENT_N_P (where N is
a number in the range of 1 to 8)
Configurable Element N (where N is a number in
the range of 1 to 8)
Pre-Alarm
COOL_SNDR_FAIL Coolant Temperature Sender Fail Status
COOL_SNDR_FAIL_A Coolant Temperature Sender Fail Alarm
COOL_SNDR_FAIL_P Coolant Temperature Sender Fail Pre-Alarm
DIAG_TRBL_CODE_P Diagnostic Trouble Code Pre-Alarm
DIAL_OUT_FAIL Modem Dialout Failed Status
DIAL_OUT_SUCCESS Modem Dialout Success Status
ECU_SHUTDOWN_A ECU Shutdown Alarm
EMERGENCY_STOP_A Emergency Stop Alarm
ENG_KW_OVERLOAD1_P Engine KW Overload 1 Pre-Alarm
ENG_KW_OVERLOAD2_P Engine KW Overload 2 Pre-Alarm
ENG_KW_OVERLOAD3_P Engine KW Overload 3 Pre-Alarm
ENGINE_RUNNING Engine Running Status
FUEL_LEAK_DETECT_A Fuel Leak Detect Alarm
FUEL_LEAK_DETECT_P Fuel Leak Detect Pre-Alarm
FUEL_LVL_SNDR Fuel Level Sender Fail Status
FUEL_LVL_SNDR_A Fuel Level Sender Fail Alarm
FUEL_LVL_SNDR_P Fuel Level Sender Fail Pre-Alarm
GENTEST Generator Exerciser Test Status
GENTESTLOADED Generator Exerciser Test with Load Status
GLBL_SNDR_FAIL_A Global Sender Fail Alarm
GN_BKR_CL_FL_P Generator Breaker Fail to Close Pre-Alarm
GN_BKR_OP_FL_P Generator Breaker Fail to Open Pre-Alarm
GN_BKR_SYN_FL_P Generator Breaker Synchronization Fail Pre-Alarm
HI_COOLANT_TMP_A High Coolant Temp Alarm
HI_COOLANT_TMP_P High Coolant Temp Pre-Alarm
HIGH_FUEL_LEVEL_P High Fuel Level Pre-Alarm
ID_MISSING_P LSM-2020 ID Missing Pre-Alarm
ID_REPEAT_P LSM-2020 ID Repeated Pre-Alarm
INPUT_N_A (where N is a number
in the range of 1 to 40)
User Configurable Input N (where N is a
number in the range of 1 to 40)
Alarm
INPUT_N_P (where N is a number
in the range of 1 to 40)
User Configurable Input N (where N is a
number in the range of 1 to 40)
Pre-Alarm
www . ElectricalPartManuals . com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Basler DGC-2020 and is the answer not in the manual?

Basler DGC-2020 Specifications

General IconGeneral
BrandBasler
ModelDGC-2020
CategoryController
LanguageEnglish

Related product manuals