3.1.4 Measurement field of the sensor
The illustration below shows the measurement field of the sensor. The sensor can be operated
in both height mode (object space) as well as in distance mode (sensor space), see also Align-
ing the sensor (height and distance mode) [}47]. Within the blind region (CD), the sensor will
not detect any objects.
Ill.8: Measurement field
RP
D
Zero point in the distance mode R2 Reference surface 2
RP
H
Zero point in the height mode MR Measuring range
CD Blind region Sde End of the measuring range
Sdc Start of the measuring range - Left; area with negative X values
FoV Field of view width + Right; area with positive X values