7 | Commissioning Baumer
30 Operating Manual OX100 | V2
c) Enter the following command: ping OXM100-[identifier].local
Replace [identifier] with the eight-digit article number or with the MAC address stated
on the sensor.
Replace OXM100 with the part of the sensor denomination before the -.
Both are found on the silver label of the sensor.
Example: pingOXM100-11218413.local or
pingOXM100-11-22-33-44-55-66.local
Result:
ü The IP address of the sensor is displayed (in the example: 192.168.0.250):
"Pinging OXM100-12345678.local [192.168.0.250] with 32 bytes of data"
The sensor might not be accessible by PC though having entered the sensor's IP address. In
this case, allocate a new IP address to your PC. Make sure to allocate your PC an IP address
that is close to the sensor's IP address, e.g.:
n
IP address of PC: 192.168.0.251
n
IP address of sensor: 192.168.0.250
7.2 Wiring the sensor
Observe the general rules for wiring.
n
The maximum cable length is 20m.
n
Use shielded cables for data transfer.
n
In cable assembly ensure the cable shield being properly connected to the connector hous-
ing.