Baumer Web interface operation | 9
V2 | OX100 Operating Manual 47
9.2.7 Aligning the sensor (height and distance mode)
With the Sensor Orientation function, you can set the mode of the sensor (height or distance
mode). When changing the mode, you alter the coordination system of the sensor.
To align the sensor, proceed as follows:
Condition:
ð The Expert Mode is activated (see Header [}34]).
Instruction:
a) Select mode Parametrization | Global Parametrization in the menu.
b) In the Global Parameters window, proceed to Field of View | Sensor Orientation.
c) Set the desired alignment.
You have a choice of the following modes:
n
Height:
In height mode (object space), the zero point of the Z axis is located in the reference surface
away from the sensor (RP
H
). The positive direction of the Z axis is pointing to the sensor.
n
Distance:
In distance mode (sensor space), the zero point of the Z-axis is at the front of the sensor
(RP
D
).The positive direction of the Z-axis is pointing away from the sensor.