9 | Web interface operation Baumer
64 Operating Manual OX100 | V2
Process Interface
n
Activation/deactivation of the process interfaces.
n
If deactivated, the sensor no longer responds to queries via
this protocol.
n
The protocols can be used in parallel.
− Modbus RTU
n
Activate/ deactivate Modbus RTU.
n
Setting the communication parameters (slave address, data
bits, number of stop bits, parity, baud rate).
n
See also Modbus RTU [}18], Set up RS485 interface with
Modbus RTU [}31].
− IO-Link process data
type
n
Switching the process data width between 16 und 32bits.
n
Restart sensor to activate.
n
Sensor logs on with the respective IODD Device ID.
Web Interface & Firmware
n
Display of the web interface software and firmware version.
n
Uploading updated web interface software (.img format) and
firmware (.fup format).
▪ It is possible to install a more recent revision of the firmware
on the sensor, as long as the compatibility of the firmware is
not excluded by the release notes.
▪ Downgrading the firmware is also possible. However, only
down to the firmware with which the sensor was delivered.
− Security
n
Activation/deactivation of Password Protection.
− Factory Reset
n
Resetting the sensor to factory settings.
− Settings Reset
n
Resetting the sensor settings. The IP address is not reset in
this process.