DC link
1C1 and 1D1
2)
Ballast
Ba+ and Ba-
1)
Max. cross-section
of connection
Connection tech-
nology
Torque Load capacity
1C1 and 1D1
2)
Ba+ and Ba-
3)
BM551X 2.5 mm
2
Terminal block - Refer to
ZEle
ctrical data
basic units–
from page 61
BM552X 4.0 mm
2
Screw terminal Min. 0.5 Nm
Max. 0.6 Nm
BM553X
BM
563X
25 mm
2
Screw terminal Min. 2 Nm
Max. 2.3 Nm
BM554X
BM564X
50 mm
2
Screw terminal Min. 6 Nm
Max. 8 Nm
BM555X
BM565X
BM575X
2 x 95 mm
2 4)6)
Cable lug
for M8
Min. 10 Nm
Max. 13 Nm
BM556X
BM566X
BM576X
2 x 185 mm
2 5)6)
Cable lug
for M10
Min. 12 Nm
Max. 25 Nm
BM557X
BM577X
2 x 185 mm
2 5)
Cable lug
for M10
Min. 12 Nm
Max. 25 Nm
Wiring diagrams
Instruction handbook b maXX BM5500, BM5600, BM5700
Document No.: 5.13008.10 Baumüller Nürnberg GmbH
190
of 314
7.11
1)
Not short-circuit-proof, consider maximum load! Refer to „Brake resistor external“ in chapter ZTechnical Da-
ta– from
page 29.
2)
Not short-circuit-proof, consider maximum load! Refer to „Connected load DC link“ in chapter ZTechnical Da-
ta– from
page 29.
3)
Refer to „Permitted brake resistor continuous power“ in chapter ZTechnical Data– from page 29.
4)
The cable lug may be 25 mm wide at most. The maximum cable diameter is dependent on the cable lug. In
case the cable lug, which you use, can safely clamp a stronger cable than 95 mm
2
, you may also use stronger
cables than 95 mm
2
. Also refer to ZCables power supply-device– from page 246.
5)
The cable lug may be 35 mm wide at most. The maximum cable diameter is dependent on the cable lug. In
case the cable lug, which you use, can safely clamp a stronger cable than 185 mm
2
, you may also use stron-
ger cables than 185 mm
2
. Also refer to ZCables power supply-device– from page 246.
6)
One cable of the mentioned cross section is sufficient for the operation.