T 8 Error detetion and trouble sho oting
Monitoring function Warning / Error
Warning
Error
Threshold adjustable
Reaction adjustable
Reaction
Setting of limit in parameter s
Activation by par ameter
Overcurrent Overcurrent motor SW
6)
— X — — PI P0358 —
Overcurrent hardware — X — — PI — —
DC link DC link overvoltage — X — — PI — —
DC link undervoltage
4)
— X X X — P1242 P297
Temperature heat sink Shutdown threshold ex-
ceeded
— X — — PI P0019 —
Temperature controller PCB Threshold 1 exceeded
2)
X — X — — P0016 —
Shutdown threshold ex-
ceeded
— X — — PI P0017 —
I
2
t-Model I
2
t-overload
7)
— X — — PI P0073 P0073
I
2
t-threshold exceeded
8)
X — — — — P0092 P0073
Temperature motor Threshold 1 exceeded
1)
X — X — — P0088 P0093
KTY84 Threshold 2 exceeded
1)
X — X — — P0089 P0093
Short circuit sensor or Temp.
< -30°C
— X — — — — P0093
Sensor not connected or
Temp. > 260°C
— X — — — — P0093
Maximum temperature ex-
ceeded
1)
— X X — PI P0090 P0093
Position controller Position deviation dynamic — X X — SH P1054 P1050
Position deviation static — X X — SH P1055 P1050
Encoder 1 Cable b reak — X — — PI — —
Cable break (sin
2
+ cos
2
) — X — — PI — —
Overspeed — X X — PI P1072 —
Encoder 2 Cable b reak — X — — PI — —
Cable break (sin
2
+ cos
2
) — X — — PI — —
Overspeed — X X — PI P1082 —
120
Instrution Manual
b maXX
®
BM3400
from 206 Doument No.: 5.07013.03
Baumueller Kamenz GmbH