T 8 Error detetion and trouble sho oting
Monitoring function Warning / Error
Warning
Error
Threshold adjustable
Reaction adjustable
Reaction
Setting of limit in parameter s
Activation by par ameter
Overcurrent Overcurrent motor SW
6)
X PI P0358
Overcurrent hardware X PI
DC link DC link overvoltage X PI
DC link undervoltage
4)
X X X P1242 P297
Temperature heat sink Shutdown threshold ex-
ceeded
X PI P0019
Temperature controller PCB Threshold 1 exceeded
2)
X X P0016
Shutdown threshold ex-
ceeded
X PI P0017
I
2
t-Model I
2
t-overload
7)
X PI P0073 P0073
I
2
t-threshold exceeded
8)
X P0092 P0073
Temperature motor Threshold 1 exceeded
1)
X X P0088 P0093
KTY84 Threshold 2 exceeded
1)
X X P0089 P0093
Short circuit sensor or Temp.
< -30°C
X P0093
Sensor not connected or
Temp. > 260°C
X P0093
Maximum temperature ex-
ceeded
1)
X X PI P0090 P0093
Position controller Position deviation dynamic X X SH P1054 P1050
Position deviation static X X SH P1055 P1050
Encoder 1 Cable b reak X PI
Cable break (sin
2
+ cos
2
) X PI
Overspeed X X PI P1072
Encoder 2 Cable b reak X PI
Cable break (sin
2
+ cos
2
) X PI
Overspeed X X PI P1082
120
Instrution Manual
b maXX
®
BM3400
from 206 Doument No.: 5.07013.03
Baumueller Kamenz GmbH

Table of Contents