Trouble shooting 8.5T
OperatingError (Error in module operating system) P0202
Error
no.
Mea ning Reaction Troubleshooting
16 Not assigned
17 Software er ror (e.g. switch) PI Restart b maXX® BM3400
18 Error configuration time-slice
operating system
PI Restart b maXX® BM3400
19 Time slot duration error PI Restart b maXX® BM3400; After
repeated occurence contact
Baumüller.
20 No more memory left PI Restart b maXX® BM3400
21 Invalid error code PI Restart b maXX® BM3400
22 Invalid warning code P I Restart b maXX® BM3400
23 Not all required type plates could be
loaded
PI Contact Baumüller.
24 Error at writing on the target
parameter two-state c ontroller output
PI Correct the parameterization of the
two-state controller (only if existing)
25–31 Not assigned
ProprogError (Error in module Proprop communication driver) P0203
Error
no.
Mea ning Reaction Troubleshooting
32 Timeout Proprog protocol Restart b maXX® BM3400
33 Protocol error Restart b maXX® BM3400
34 Incorrect module type Contact Baumüller.
35 Too many data in the list or telegram Contact Baumüller.
36 Not enough data in the list or telegram Contact Baumüller.
37 Invalid operand Contact Baumüller.
38 Invalid memory type Contact Baumüller.
39 Invalid operand address (log. address) Enter a valid address.
40 Value < Minimum value Check the data set and c orrect the
value.
41 Value > Maximum value Check the data set and correct the
value.
42 Parameter is read-only Check the data set and adjust it.
Instrution Manual
b maXX
®
BM3400
129
Doument No.: 5.07013.03 from 206