Section VIII
Handling, Serv -
Maint
ALTERNATOR
BEECHCRAFT
Debonair
C33
Bonanza
E33
and
F33
Since
the
alternator and voltage regulator are designed
for
use on only
one
polarity system,
the
following
precautionary measures must be observed
when
working
on the charging circuit,
or
serious damage to the electrical
equipment
will
result:
1. When installing a battery, make certain
that
the
ground.polarity of
the
battery and
the
ground polarity
of
the
alternator are the same.
2. When connecting a booster battery, be sure
to
connect
the negative batterv
terminals together and
the
positive battery
terminals
together.
3. When using a battery charger. connect
the
positive
lead
of
the
charger
to
the positive battery
terminal
and
the negative
lead
of
the
charger to the negative battery
terminal.
4.
Do
not operate
an
alternator on open circuit.
Be
sure
all circuit connections are secure.
5.
Do not short across
or
ground any of
the
terminals
on
the
alternator
or
voltage regulator.
6.
Do
not
attempt to polarize an alternator.
MAGNETOS
Ordinarily,
the magnetos
will
require only occasional
adjustment, lubrication, and breaker
point
replacement.
This
work
should be done by a BEECHCRAFT
Aero
or
Aviation Center or
International
Distributor or Dealer.
8-28
August