BEECHCRAFT
Debonair
C33
Bonanza
E33
and
F33
SectionlV
Normal
Procedures
11. Battery and Generator/Alternator Switches -
ON
(lt
\.__.
external power
is
used,
turn
Generator/Alternator
Switch
-
OFF.
See Section 7 and the precautions
below.)
12. Fuel
Ouantity lndicators - CHECK OUANTITY
WARNING
Do
not
take
off
if
gages indicate
in
yellow arc or
with
less than 13 gallons
in
each tank.
EXTERNAL POWER
When using external power, it is
verv
important that the
following
precautions
be
observed:
1.
The airplane has a negative ground system. Exer-
cise care
to
avoid reversed polarity.
Be
sure to con-
nect
the
positive lead
of
the external power
unit
to
the
positive terminal of
the
airplane's external power
receptacle and the negative lead to the negative ter-
minal
of
the
external
power
receptacle. A positive
voltage must also be
applied
to
the small guide pin.
2.
To
prevent arcing, make certain no power
is
being
supplied
when
the
connection is made.
3. Make certain that
the
battery switch is ON, all avi-
onics and electrical switches
OFF,
and a battery is in
the system before connecting an external power
unit. This protects the voltage regulators and
associ-
ated electrical equipment from voltage transients
(power fluctuations).
August
1982