Sectionlll
BEECHCRAFT
Debonair
C33
Bonanza
E33
and
F33
Emergency Procedures
LANDING GEAR MANUAL EXTENSION
Manual
extension of the landing gear can be facilitated by
first reducing airspeed. Then proceed as
follows:
1.
LOG
GEAR Circuit Breaker -
OFF
(PULL OUT)
2.
Landing Gear
Switch
Handle - DOWN position
3.
Handcrank Handle Cover (at rear
of
front
seats) -
REMOVE
4. Handcrank - ENGAGE and TURN COUNTERCLOCK-
WISE AS
FAR
AS POSSIBLE (approximately
50
turns)
CAUT/ON
The
manual
extension
system
is
designed
to
lower
the
landing,gear only. DO NOT ATTEMPT
TO
RETRACT
THE
GEAR MANUALLY.
5.
lf
electrical system is operative, check landing gear
position lights and
warning
horn
(check LOG GEAR
INDICATOR and
LOG
GEAR WARNING
circuit
breakers
engaged).
6.
Check mechanical landing gear indicator - DOWN
7.
Handcrank - DISENGAGE.
Always
keep
it
stowed
when
not in use.
3-10
WARNING
Do
not
operate
the
landing gear electrically
with
the handcrank engaged, as damage
to
the
mechanism could occur.
After
emergency
landing gear extension, do not move any
landing gear controls or reset any switches or
circuit breakers
until
airplane is
on
jacks as
failure may have been in
the
gear
up
circuit
and gear might retract on
the
ground.
August