51
SYSTEM CONTROL COMMAND:
Command Description
==================================================
CADR followed by address, which can be 1 to 30 and
is used to access the power supply
CCLS Clear status
CRST Reset command. Brings the power supply to a
known state
CIDN? Returns the power supply model identification
CREV? Returns the firmware version
CSN? Returns the serial number
CST? Returns the device status
CCLR? Clear protect
==================================================
OUTPUT CONTROL COMMAND:
Command Description
==================================================
CPV Sets the output voltage value in Volts
CPV? Reads the output voltage setting
CMV? Reads the actual output voltage
CPC Sets the output current value in Amperes
CPC? Reads the output current setting
CMC Reads the actual output current
CDVC? Display voltage and current data
COUT Turns the output to ON or OFF
COUT? Returns the output On/Off status
COV Sets the OVP level
COV? Returns the OVP setting level
COVP Sets the OVP on/off
COVP? Returns the OVP on/off
COC Sets the OCP level