34 en | Panel and Area Wide Parameters D9412GV4/D7412GV4/D7212GV4
F.01U.218.312 | 04 | 2012.03 Program Entry Guide Bosch Security Systems, Inc.
Burglar Reports
Select Yes to send a report when the event occurs. Refer to Table 3.7, Page 34.
Table 3.7 Burglar Reports
User Reports
Select Yes to send a report when the event occurs.
Table 3.8 User Reports
Report Selection Report Description
R# Alarm Yes, No Burglar Alarm Event
R# Burg Restore Yes, No Non-fire restoral from trouble, missing, or supervisory
R# Duress Yes, No Duress
R# Missing Alarm Yes, No Missing Alarm point
R# Usr Code Tmpr Yes, No User code tamper
R# Trouble Report Yes, No Trouble Event
R# Missing Trbl Yes, No Missing Trouble Event
R# Non Fire Suprv Yes, No Non-fire Supervisory Event
R# Pt Bus Fail Yes, No Point bus failure
R# Pt Bus Rstl Yes, No Restoral of point bus after failure
R# Non Fire Cncl Yes, No Canceled non-fire alarm
R# Alarm Restore Yes, No Non-fire restoral from alarm
R# Sup Missing Yes, No Supervisory missing
R# Unverified Evt Yes, No Unverified Events for Cross Points
NOTICE!
R# Unverified Evt is sent when a single point programmed in Cross Point Group faults into an
alarm condition, then restores before the Cross Point Time elapses.
R# Unverified Evt encompasses both Fire and Non-fire points, but is not related to the A#
Verify Time used for smoke detectors.
NOTICE!
Restoral Reports are not sent if the control panel resets after a point is bypassed and then
unbypassed. This is true for both Fire and Non-fire points.
Report Selection Report Description
R# Point Bypass Yes, No Point Bypass Event
R# Forced Point Yes, No Forced Point Event
R# Point Open Yes, No Point Opening Event
R# Point Close Yes, No Point Closing Event
R# Forced Arm Yes, No Point Force Armed
R# Fail To Open Yes, No Fail to Open Event
R# Fail To Close Yes, No Fail to Close Event
R# Ext ClosTm Yes, No Extend Close Time Event
R# Opening Report Yes, No Opening Events
R# Forced Close Yes, No Point Forced Close Event
R# Closing Report Yes, No Closing Events
R# FC Perimeter Inst Yes, No Forced Close Perimeter Instant Armed Event
R# FC Perimeter Delay Yes, No Forced Close Perimeter Delay Armed Event
R# Perimeter Inst Arm Yes, No Perimeter Instant Armed Event
R# Perimeter Delay Arm Yes, No Perimeter Delay Armed Event
R# Send User Text Yes, No User text