EasyManua.ls Logo

Bosch D9412GV2 - S## Access Ctl Level; S## CMD Center 1[Through 8]

Bosch D9412GV2
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D9412GV2/D7412GV2 | Program Entry Guide | 5.0 RADXSKED EN | 113
Bosch Security Systems | 5/05 | F001U003636B
Default: Blank
Selection: 1 to 11, 13 to 24, 28, 29
14 Adjust Time Backward One Hour: This sked function is used to make adjustments to the control
panel’s clock. A typical application is to program this to go into effect at 2:00 AM on the date that
Daylight Saving Time ends (during the fall). This function can operate only once in a day, even if
multiple Skeds with this function are programmed. No Time Change Report is sent or logged, but the
new time appears in the next report logged.
There are no other parameters that require input for this option.
S## Cmd Center 1[through 8]
Default: Blank
Yes
Watch tone
sounds at this
keypad.
15
Sound Watch Tone at
Command Center (Keypad): This
function sounds the Watch Tone at
the keypad address programmed
in Parameter 1. The Watch Tone
sounds at all keypads with the
address programmed. Press [ESC]
to silence the tone.
Sound Watch Tone defines the
keypad address where the Watch
Tone sounds. Enter the specific
address at the
S## Cmd Center
prompt.
Selection: Yes or No
Enable the sked to beep the keypad
programmed Yes.
No
Watch tone
does not sound
at this keypad.
S## Access Ctl Level #
Default: No
Yes
Enable Access
Control Level #
16
Access Control Level On: This
function emulates the ACCESS
CMD LEVEL command that
determines whether a user’s token
or card level is ENABLED?,
allowing access granted rights.
This affects all doors that this user
is assigned to with this specific
authority level.
Selection: Yes or No
Activate a sked, which enables the
Access Level(s) 1 through 14 with Yes.
No
Do not enable
Access Control
Level #.
The D9412GV2 supports eight doors; the D7412GV2 supports two doors.
To regulate a user’s access for certain doors, assign the user a different authority level # with the
same authority functions enabled. For example, a user can be assigned Authority Level 1 for Door 1
and Authority Level 2 for the remaining doors. You can enable or disable Authority Level 1 for Door 1
without affecting his authority level for Doors 2 through 8).
Default: Blank
Selection: 1 to 11, 13 to 24, 28, 29
S## Access Ctl Level#
Default: No
Yes
Turn off access for
level #.
17
Access Control Level Off: This
function emulates the ACCESS
CMD LEVEL command that
determines whether a user’s token
or card level is disabled. This
function allows access to be
turned off for the levels
programmed.
Selection: Yes or No
The first parameter enables the sked to
turn off access for Levels 1 through 14.
No
Do not turn off
access for level #.

Table of Contents

Other manuals for Bosch D9412GV2

Related product manuals