D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 42
Bosch Security Systems | 5/05 | F001U003636B
A# Fail to Close
Default: No
Selection:
Yes or No
Yes Fail to Close Report is sent for this
area if the area was not armed when
the Closing Window stop time
occurred.
Note:
Program an exit delay time in
Exit
Dly Time
.
No Fail to Close Report is not sent for this
area.
If
Auto Close
is programmed
Yes, a Fail to Close Report is sent
because it occurs when the Closing
Window stop time occurred.
If
Disable O/C in Window
is
Yes, the Fail to Close Report is
followed by Closing Late or
F(orce) Close Late.
Determines if a Fail to Close Report is sent for this
area. Use to determine if a user failed to arm the area
before the Closing Window expires. Normal Opening
and Closing Reports do not need to be programmed to
use this feature.
A# Restrictd O/C
Default: No
Selection:
Yes or No
Yes Restrict Opening and Closing Reports
for this area.
A# Area O/C
must be
programmed Yes to generate
Restricted Opening and Closing
Reports.
Note:
If a passcode is not required for
arming or disarming and this item
is Yes, the area sends only
Restricted Opening and Closing
Reports. In this case, Restricted
Reports are sent without User ID.
Opening/Closing Window does not
affect this report. Windows do not
prevent sending Restricted Opening
and Closing Reports from being sent.
Early or late designations are not
added to Opening or Closing Reports
when they are sent according to the
rules for Restricted Opening or Closing
Reports.
No Do not Restrict Opening and Closing
Reports for this area.
Regardless of programming in
Authority Levels
L## Restricted O/C
,
reports are not restricted in this area
when this item is programmed as No.
Note:
Was Force Armed and Forced
Close Events can still be sent to the
central station if enabled in
Routing
when force arming the
system.
This item determines if this area can restrict Opening
and Closing Report activity.
A Restricted Opening Report refers to the control
panel sending an Area Opening Report only when the
area is disarmed after a non-fire alarm.
A Restricted Closing Report refers to the control panel
sending an Area Closing Report only when the area
was master armed with Controlled points that were
faulted during the arming sequence. The sequence of
reports generated by a restricted closing is: Was Force
Armed, Forced Point, Forced Close, and Closing
Report.