D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 65
Bosch Security Systems | 5/05 | F001U003636B
Table 27: L## Secure Door-Door Mode
Definitions
Door State Definition
Lock Door
Normal Door: When a door is in the
Lock Door state, one can initiate the
door sequence using Skeds, CYCLE
DOOR?, keypad functions, door
requests, and valid token or card
requests.
Secure
Door
No Access Allowed: When a door is
in the Secure Door state, no access is
allowed through the door until it is
returned to the Lock Door state. The
Secure Door state includes Sked and
keypad functions.
Unlock
Door
Free Access: When a door is in the
Unlocked Door state, the door is
already shunted and the door strike
does not prevent the door from
opening. In this state, the user does
not need to activate a door request or
present a valid token or card.
Cycle Door
Momentary Access: This is a
temporary Door Mode in which the
door initiates the door sequence as if
a valid token or card was read. This
state occurs using the keypad and
remote programming software (RPS).
A sked cannot activate this state.
L## Access Ctl Lvl
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
37 Access Control
Levels
(Menu function only)
Changing the Access Control Level in any
area affects all users and all doors
associated with that level for all areas.
General Functions
L## Chg Display
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
15 Change Display [COMMAND][4][9]
Change the display (bright display, dim display, and
time display) in the area where this keypad is assigned.
L## Chg Time/Date
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
16 Change Time and
Date
[COMMAND][4][5]
Change the date and time for the control panel in this
area.
L## Chg Passcode
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
17 Change
Passcodes
[COMMAND][5][5]
Change a user pass code.
L## Add User
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
18 Add User [COMMAND][5][6]
Add or change users, add or change authority levels,
add or change tokens or cards.
9210 NOT READY appears if a door
controller is not assigned to the keypad
used to add or change tokens or cards.
Refer to CC# Assign Door in Section
2.10.1 Keypad (Command Center)
Assignment on page 45.