D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 66
Bosch Security Systems | 5/05 | F001U003636B
L## Del User
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
19 Delete User [COMMAND][5][3]
Delete users.
Although an individual user (001 through
249) can be deleted separately, use
caution with this function. User pass codes,
tokens or cards cannot be deleted
individually within a group. (For example,
User 001 has three additional sub-users
that use the same authority levels for that
group.) When dealing with an individual
user, change that user’s token or pass
code so that other users in the group do
not need to be added again.
L## Extend Close
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
20 Extend Close [COMMAND][5][1]
Change the closing time in the area where the function
is entered.
L## View Log
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
21 View Log (Menu function only)
View all panel-wide events in the control panel’s
memory log.
L## Print Log
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
22 Print Event Log (Menu function only)
Print all panel-wide events from the log to the printer
in the area where the user is executing this function.
This item can also be accessed using the
Service Menu ([9][9][ENT]).
L## User Cmd 7
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
23 User Command 7 [COMMAND][7]
This command can be used in Function Menu.
Generate the alarm programmed at COMMAND 7 in
the RADXPNTS Handler.
L## User Cmd 9
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
24 User Command 9 [COMMAND][9]
This command can be used in Function Menu.
Generate the alarm programmed at COMMAND 9 in
the RADXPNTS Handler.
L## Bypass a Pt
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
25 Bypass a Point [COMMAND][0]
Bypass points with this authority level
L## Unbypass a Pt
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
26 Unbypass a Point [COMMAND][0][0]
Unbypass points with this authority level.
L## Reset Sensors
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
27 Reset Sensors [COMMAND][4][7]
Reset sensors with this authority level.