L## Master Arm Delay
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
2 Master Arm Delay [COMMAND][1]
Master arms areas based on the
CC# Scope
of the
keypad using an exit delay time.
When this item is accessed through the Function List,
Master Arm All allows the user to arm all areas
according to the authority level of the user and within
the
CC# Scope
of the keypad using an exit delay
time.
Arm Area arms only the area displayed. If
COMMAND 1 is used, it arms only the area where
the keypad is assigned.
L## Mstr Arm Inst
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
3 Master Arm
Instant
[COMMAND][1][1]
This authority level permission allows a user to
execute the Master Arm Inst function. Refer to Mstr
Arm Inst on page55.
Arm Area arms only the area to which the keypad is
assigned.
If COMMAND 11 is used, it arms only the area where
the keypad is assigned.
Use COMMAND 11 carefully because all
Perimeter and Interior points become
Instant Armed.
L## Perim Instant
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
4 Perimeter Instant
Arm
[COMMAND][2]
Instant arm all Perimeter points, including Delayed
points, only in the area where the keypad is assigned.
L## Perim Delay
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
5 Perimeter Delay
Arm
[COMMAND][3]
Delay arm all Perimeter Delay point responses only in
the area where the keypad is assigned.
L## Watch Mode
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
6 Watch Mode [COMMAND][6]
Initiate the Watch Mode in the area to which this
keypad is assigned.
L## Perim Partial
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
7 Perimeter Partial
Arm
[COMMAND][8]
Partially arms only the area where the keypad is
assigned.
This function ignores the A# FA Bypass
Max entry in Area Parameters.
Local Only Reporting: No Closing Report
is sent to the central station, but a
Perimeter Delay Closing Event is generated
in the event log.
L## View Area Stat
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
8 View Area Status (Menu function only)
View the current arm or disarm status and the not
ready to arm status of all areas within the scope of the
keypad in this area. The user needs arming and
disarming authority.