D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 61
Bosch Security Systems | 5/05 | F001U003636B
Custom Functions
C Function 128 [through 143]
Default: E
Selection:
Blank, E, or P
Function No. Function Name Alternate Keystroke
128 through
143
Enable Custom
Functions 128
through 143
(Menu function only)
When enabled, Custom Function determines if a pass
code is required when accessing a custom function
from the menu list. ENTER PASSCODE (or Enter
Passcode + Enter Key on the D1260) appears
when this function is pass-code protected. If a
command within the Custom Function is pass-code
protected, the keypad displays ENTER PASSCODE (or
Enter Passcode + Enter Key on the D1260)
and waits for the user to enter a valid pass code before
proceeding with the rest of the Custom Function. If a
pass code is not entered within 10 seconds, the
Custom Function times out and the display returns to
idle text.
2.11.4 Authority Level Selections
Use Section 2.11.4 Authority Level Selections on page 61
to determine which Authority Level can access keypad
functions that are pass-code protected. Selecting
Enable items in the Authority Level section is not
necessary if the keypad function is disabled or
enabled. Each individual function has two selections
you can use for the authority level you are
programming.
Press the [SPACE] bar to scroll through the selections.
Press [ENTER] when the correct selection appears in
the display.
Table 26: Authority Level Selections
Authority
Level
Description
Blank
Disabled: This function is not
authorized for the user who is
assigned this authority level.
E
Enabled: This function is authorized
for the user who is assigned this
authority level.
Authority Level
Default: 1
Selection:
1 to 14
Enter the number of the authority level you want to
program. Authority Level 15 (Service Passcode) cannot
be edited.
To determine the L## default values on
pages 61 through 70, refer to the User
Interface section for the GV2MAIN Handler
in the program record sheet.
L## Disarm
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name
1 Disarm
Use the disarming function to disarm areas that are
master armed or perimeter armed. If enabled, the
following disarming choices are available to the user
with this authority:
DISARM ALL: Disarms all areas within the
CC#
Scope
of the keypad being used by accessing the
Function Menu and the authority level of the user
performing the function.
DISARM AREA: Disarms only the displayed
area.
Many options are available for arming and
disarming. Selecting an option depends on
A# Area Type and CC# Scope. Read the
definitions of area type in Section 2.9 Area
Parameters on page 5 and CC# Scope in
Section 2.10.1 Keypad (Command
Center) Assignment on page 45.

Table of Contents

Other manuals for Bosch D9412GV2