D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 50
Bosch Security Systems | 5/05 | F001U003636B
CC# Passcode Follows Scope
Default: Yes
Selection:
Yes or No
Yes Master Arming allows a user to change
the armed state of the areas within the
scope of this keypad. If the areas in the
scope are already at the intended
armed state, they remain in that state.
• If the area to which this keypad is
assigned is armed, entering a valid
pass code disarms this area and all
other areas assigned to the scope
of this keypad.
• If the area to which this keypad is
assigned is disarmed, entering a
valid pass code arms this area and
all other areas assigned to the
scope of this keypad.
No Restricts the scope of the keypad to
the Area programmed in
CC# Area
Assign
for the purpose of executing
L## Passcode Arm
and
L## Passcode Disarm
only.
Use this program to determine if this keypad follows
CC# Scope or if it only arms or disarms the area to
which it is assigned. The user must have authority
enabled in L## Passcode Arm and L## Passcode
Disarm.This feature does not affect the Function List
arming and disarming commands.
Tokens and cards disarm according to this
prompt. If this prompt is No, tokens disarm
only the Area to which the CC# is
assigned. The user must have disarming
rights for tokens and cards programmed at
the Disarm Level,. The user does not need
disarming and arming authority for the
keypad.
You can use this prompt for a group of
account-wide keypads that only arm the
area to which they are assigned, even if the
user has a pass code with arming authority
rights in all areas.
CC# Menu Key Lock
Default: No
Selection:
Yes or No
Yes
If set to Yes, the user is prompted to
enter a pass code after pressing the
Menu key on the keypad. The items
programmed in the Menu List for this
specific keypad are filtered by the
user’s authority level. Only those
items in the menu list for which the
user has authority appear.
No
If set to No, when the user presses
the Menu key, all items that are
programmed in the Menu List for the
Command Center Address (Keypad
Address) appear, regardless of the
user’s authority level.
Determines if the Menu Key, when pressed, requires a
pass code to access the functions.
If this parameter is set to Yes, users must
enter a pass code after pressing the Menu
key. When the pass code is validated, only
those functions for which the user has
authority appear in the list. If a function in
the Menu List is pass-code protected (refer
to Keypad Functions in Section 2.11.2
User Interface on page) the user does not
need to enter the pass code again.
2.10.2 Area Text
Use this programming category to create custom Idle
Text displays for the keypads.
Each display can be programmed with up
to sixteen alphanumeric characters,
including: A to Z, 0 to 9, ?, &, @, -, *, +,
$, #, _, /.
Characters not listed are invalid and cannot
be used for text.