Bosch D9412GV2 - Effects of Programming on Custom Function Activation; D# Door Point; D# Interlock Point

Bosch D9412GV2
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D9412GV2/D7412GV2 | Program Entry Guide | 7.0 RADXAXS EN | 136
Bosch Security Systems | 5/05 | F001U003636B
Table 42: Effects of Programming on Custom
Function Activation
L## Function
Level?
Custom Function Activation
M
(Armed)
User token activates the custom
function assigned to the Door
Controller only while the entry area for
the Door Controller is Master Armed
or Perimeter Armed.
D
(Disarmed)
User token activates the custom
function assigned to the Door
Controller only while the entry area for
the Door Controller is disarmed.
C
(Armed and
Disarmed)
User token activates the custom
function assigned to the Door
Controller regardless of the armed
state of the entry area.
Blank
User token does not run the custom
function assigned to the Door
Controller.
A user’s security level must have an M, P,
or D to operate the custom function.
D# Door Point
Default: Blank
Selection: Blank, 1 to 127, 129 to 247
1 to 127,
129 to 247
The point number assigned to this
door. Points 128 and 248 are
reserved by the control panel for
internal use.
Blank
No point number is assigned to this
door.
Enter the point number assigned to this door. This
point cannot be used for any other point assignments.
Door points must be programmed as
Perimeter points. If a 24-hour point type is
required for the Door point, you can use a
Perimeter point type with a point response
of 9 to C. Also, the debounce count must
be set to 4 in Point Assignments.
When assigning Points 1 to 8 (control
panel zones), the end-of-line (EOL)
resistors must be removed from the control
panel.
Also, do not enable any POPIT points (or
OctoPOPIT points) sharing the same point
number as the Door point. Failure to do so
results in extra point trouble conditions
upon reboot.
D# Interlock Point
Default: Blank
Selection: Blank, 1 to 127, 129 to 247
1 to 127,
129 to 247
The point number assigned to the
Interlock point. Points 128 and 248
are reserved by the control panel for
internal use.
Blank
No point number is assigned to the
Interlock point.
Enter the interlock point number. This point, when
faulted, prevents the door controller from allowing
access upon a valid ID read or door request.
Do not assign this point to another Door point. You
can assign it to another controller. One Interlock point
prevents multiple controllers from activating.
Door points must be programmed as
Perimeter points. If a 24-hour point type is
required for the Door point, you can use a
Perimeter point type with a Point Response
of 9 to C. Also, the debounce count must
be set to 4 in Point Assignments.
The Interlock point is considered in a normal
state if it is bypassed, swinger bypassed, or
forced armed. This results in normal access
even if the door remains open.