D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 17
Bosch Security Systems | 5/05 | F001U003636B
Test Reports
To send a single Test Report (
R# Test Report
),
enable Sked Function Code #9 (Test Report) in the
Skeds section of the program. Refer to Table 11.
To expand this Test Report to include any off-normal
point condition or other off-normal conditions of
events listed in Diag Reports as a Non-status Event
following a Test Report,
Expand Test Rpt
in Section
2.2 Phone Parameters on page 10 must be programmed
Yes. Refer to Table 12 on page 18.
Events R# Log Threshold, R# Log Overflow, and R#
RPS Fail are added to the reports sent with Expanded
Test Reports if
RPS Reports
and
Expand Test Rpt
are enabled.
To initiate a Status Report that includes all R# S: ____
Events as a Status Event, Sked Function Code #10
must be enabled in the Skeds section of the program.
Sending off-normal conditions as a Status Report
following a Test Report is required by some
automation systems. Sending off-normal conditions as
a Non-status Report that follows a Test Report is
required for other automation systems.
An off-normal condition is any point that is missing,
trouble, supervisory, or in alarm. Also, points not
cleared at the keypad report as off-normal.
The control panel can generate an Expanded Off-
Normal Test Report by using Sked Function Code 28
or a Non-Expanded Off-Normal Test Report using
Sked Function Code 29. To generate this event, one or
more points must be in an off-normal state at the time
the Sked executes. Expanded Off-Normal Test Reports
include the Off Normal Test Report Event as well as
events for any points that are in an off-normal state at
the time the report is generated. Non-Expanded Off-
Normal Test Report Events are sent only when a point
is in the off-normal state but sends only the Off-
Normal Test Report Event.
Table 11: Test Reports
Report Selections Report Description
R# S: Alarm
Yes, No
Status Alarm
R# S: Trouble
Yes, No
Status Trouble
R# S:
Supervised
Yes, No
Status Supervised
R# Status
Report
Yes, No
Status
R# S: Open
Yes, No
Status Open
R# S: Close
Yes, No
Status Close
R# Test
Report
Yes, No
Test
R# S: Perim
Inst
Yes, No
Status Perimeter
Instant Arm
R# S: Perim
Delay
Yes, No
Status Perimeter
Delay Arm
R# S: Fire
Supv
Yes, No
Status Fire
Supervision
R# S: Fire
Alarm
Yes, No
Status Fire Alarm
Report
R# S: Fire Trbl
Yes, No
Status Fire Trouble
R# S: Msng
Fire
Yes, No
Status Fire Missing
R# S:
MsngBurgTr
Yes, No
Status Burg Missing
Trouble
R# S:
MsngBurgAl
Yes, No
Status Burg Missing
Alarm
R# S:
FireSpMsng
Yes, No
Status Fire
Supervision Missing
R# S:
SuperMsng
Yes, No
Status Non-fire
Supervision Missing
R# S:
DrLeftOpen
Yes, No
Status Door Left
Open
Diag Reports
Selecting Yes enables sending a report when the event
occurs. If the off-normal state of the following events
(indicated with an *) still exist, they report when a Test
Report (refer to the
Test Reports
sub-prompt in
Section 2.3.8 Dialing Attempts on page 14) is enabled and
Expanded Test Rpt is programmed Yes.