D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 68
Bosch Security Systems | 5/05 | F001U003636B
L## Default Text
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
34 Default Text [COMMAND][5][7]
Temporarily show the armed state of the area using
control panel default text, A# AREA # IS ON, A#
NOT READY, A# AREA # IS OFF, and A#
ACCOUNT IS ON.
L## Change Skeds
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
35 Change Skeds [COMMAND][5][2]
Change skeds that can be edited.
Editing of skeds can be restricted by
programming S## Time Edit? to No.
L## Invisible Walk Test
Default: Refer to the program record sheet
Selection:
Blank, or E
Test all points that are programmed to be invisible and
that are within the scope of the keypad without
sending reports to the central station. Invisible points
must be programmed P## Invisible Pt as Yes. This
walk test mode can test 24-hour points and controlled
points.
Invisible Test? allows the user with this L## to start
an invisible walk test for all 24-hour interior and
posterior controlled points in the area to which this
keypad is assigned. When an invisible test is started,
one person can test invisible points without assistance.
The following features are provided with the Invisible
Test Mode:
The display indicates exactly how many invisible
points are assigned to the area.
Battery and bell tests do not occur during this walk
test.
The keypad shows point text when invisible points
are tested.
The test ends when all points are tested, or if the
test times out after ten minutes of no activity.
Local event printing occurs without alarm
annunciation or reports sent to the central station
receiver.
The D1255 Keypad shows a sequential count and
text related to the point after each point is
actrivated and restored.
The keypad shows All PTS TESTED. An All
Points Tested Event is sent to the central station
receiver (if programmed) when the last point is
tested.
Walk Start and Walk End Reports are sent to the
central station receiver for the beginning and end
of the test (if programmed in phone routing).
Custom Functions
L## C Function 128 [through 143]
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
128 through
143
Enable Custom
Function 128
through 143
(Menu function only)
Execute the desired Custom Function.
Report Levels
L## Force Arm
Default: Refer to the program record sheet
Selection: Blank or E
A user with this authority level can Force Arm.
L## Area O/C
Default: Refer to the program record sheet
Selection: Blank or E
Generates Opening and Closing Reports if the area
where this authority level is assigned sends Opening
and Closing Reports.
L## Restricted O/C
Default: Refer to the program record sheet
Selection: Blank or E
Generates an Opening Report if a bell is ringing or a
Closing Report when force or bypass arming. The area
where this authority level is assigned must be
programmed for restricted openings and closings (refer
to the
A# Restrictd
O/C
prompt in Section 2.9.5
Open/Close Options on page 39.