D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 33
Bosch Security Systems | 5/05 | F001U003636B
Although the D5200 allows the character
“A” to be entered into the account, do not
use this character for the account number.
Any account number digits containing “A”
for digits 1 to 6 that were uploaded to and
received by RPS are not displayed.
If an “A” is sent erroneously to the control
panel from the D5200 for any of Digits 1 to
6, correct this by:
Entering six leading 0s from the
D5200 and sending them to the
control panel,
or
Entering six leading 0s from RPS,
followed by the four-digit account
number, and sending them to the
control panel.
Programming Ten-Digit Account Numbers
To program a ten-digit account number (such as
1122334455) using the D5200 Programmer, you must
enter a character for each of the ten digits. Refer to
Table 21:
Table 21: Programming Ten Digit Account
Numbers
D5200 Programmer
A# Acct# Dgt 1&2 1 1
A# Acct# Dgt 3&4 2 2
A# Acct# Dgt 5&6 3 3
A# Acct# Dgt 7&8 4 4
A# Acct# Dgt 9&10 5 5
The D5200 account number entry shown in Table 21
appears in RPS as shown in Figure 2.
Figure 2: Account Number Entry
22 33 44 5511
2
3 4 5 6 7
1
1 - RPS account number entry
2 - Corresponding D5200 account number digits
3 - Digits 1 and 2
4 - Digits 3 and 4
5 - Digits 5 and 6
6 - Digits 7 and 8
7 - Digits 9 and 10
Although the D5200 allows the character
“A” to be entered into the account, do not
use this character for the account number.
A# FA Bypass Max
Default: 1
Selection:
1 to 99
Specify the maximum number of combined Controlled
points that can be faulted or bypassed when arming
this area.
Refer to the prompts
P## FA Retrnable
and
P## BA
Retrnable
in Section 4.2 Point Responses on page 85
for returning a point to the system when the point
returns to normal or when the area is disarmed.
Users can bypass more points than the
number entered here during the disarmed
state. It is only when the user attempts to
Bypass Arm an area (or areas) that this
restriction is enforced.
A# Delay Res
Default: No
Selection:
Yes or No
Yes Point Restoral Report is not sent until
the bell time expires or user
acknowledges alarm condition.
No Restoral Reports are sent when point
restores, regardless of bell time.