D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 31
Bosch Security Systems | 5/05 | F001U003636B
RPS Ph
Default: Blank
Selection:
Blank or up to 24 characters
Blank Control panel does not dial a phone
number for RPS.
1 to 24
characters
Enter up to 24 characters to define
dialing characteristics.
This is the phone number the control panel dials to
contact RPS. The control panel dials the programmed
number on
Phone #5
(
RPS Ph #
) when any of the
following events occur:
• Log % Full threshold is achieved.
If Log % Full was programmed with a
value (1 to 99) and an RPS phone
number is programmed, the control panel
dials the RPS phone number when the
log threshold is reached. This function is
not available in RPS. Do not program Log
% Full and an RPS phone number at the
same time.
• The control panel is contacted by RPS and RPS
Call Back is programmed Yes.
• The user enters COMMAND 43 and selects the
call RPS option from the menu. On the D1255:
1. Press [COMAND][4][3].
2. Press [NEXT] until CONTACT RPS? appears,
then press [ENTER].
3. Wait for RPS VIA PHONE? to appear, then
press [ENTER].
The control panel tries to contact RPS only
once using this method.
Refer to Section 6.4 SDI RPS Parameters on page 121 for
other corrections methods.
Refer to Phone 1 in Section 2.1 Phone.
2.8 Miscellaneous
Duress Type
Default: 1
Selection:
1 or 2
1 Increase the last digit by 1 to generate an alarm.
For example, if the passcode is 6123, 6124
activates a duress alarm.
If the last digit of the passcode is 0, a duress
alarm occurs when the user enters 1 as the last
digit of the passcode.
If the last digit of the passcode is 9, a duress
alarm occurs when the user enters 0 as the last
digit of the passcode.
2 Increase the last digit by 2 to generate an alarm.
For example, if the passcode is 6123, 6125
activates a duress alarm.
If the last digit of the passcode is 8, a duress
alarm occurs when the user enters 0 as the last
digit of the passcode.
If the last digit of the passcode is 9, a duress
alarm occurs when the user enters 1 as the last
digit of the passcode.
This program item determines if users add one (+1) or
two (+2) to the last digit of the passcode. To activate a
duress alarm, the user increases the value of the last
digit of the passcode when entering it at the keypad.
Duress is enabled in Area Parameters by
setting A# Duress Enable to Yes.
The duress alarm activates when a user
enters the duress passcode followed by the
termination keys ([ESC] or [ENT]).