D9412GV2/D7412GV2 | Program Entry Guide | 3.0 RADXUSR1/RADXUSR2 EN | 77
Bosch Security Systems | 5/05 | F001U003636B
3.0 RADXUSR1/RADXUSR2
3.1 Pass Code or Token Worksheet
These programming items assign:
a pass code touser groups 001 to 249,
areas by authority level, and
a User Group Window.
Two handlers in the D5200 Programmer are used to
program the users:
RADXUSR1 Handler programs users 000 to 124.
RADXUSR2 programs users 125 to 249
(D9412GV2 only).
3.1.1 User Groups
For the D9412GV2, there are 249 groups (99 groups
for the D7412GV2) consisting of one user with a pass
code and token (master) and three users with tokens or
cards but not a pass code (sub-user). All users in the
group share the same authority level as the master
user.
3.1.2 Pass Codes
In a control panel with factory default settings, only
the master user has an assigned pass code. A pass code
can be three to six digits. Entering three digits in
User
###
chooses the user. Programming the
U001
Passcode
assigns a pass code to the master user. Sub-
users cannot use the pass code. Do not assign tokens or
cards to User ID 0 (zero), which is reserved for the
service pass code.
Pass Code Tamper
If a user enters six consecutive invalid pass codes at
the same keypad, the control panel sends a User Code
Tamper report to the cental station. The invalid pass
code count resets when a valid pass code is entered at
the same keypad. Refer to R# Usr Code Tamper in
Table 9 on page 16 for information on enabling this
report.
3.1.3 User Group Window
Use
U### User Group
to enable and disable the
U### Passcode
for up to eight different time periods
throughout the day. Assign the number (1 to 8)
programmed in
U### User Group
to a
User
Windows #
. If the user is outside a window, COMMAND
DISABLED appears on the keypad after the user enters
the pass code and presses [ENTER].
This window does not affect tokens and
cards. It only affects the pass code of the
master user.
When using the Add/Change User function
at the keypad, the authority levels and the
changes made affect the master user’s pass
code and the entire group’s token or cards.
When using the ACCESS CTL LVL function
at the keypad, the whole group is affected
by whether or not the level is on or off for
access control functions only.
When using the DELETE USER? function,
the whole group is deleted. You cannot
delete each user within the group
individually. Use the ADD/CHG USER?
function to change a user token or card
instead of deleting the whole group.
3.1.4 User Name
Each user group can be assigned one
U### Name
.
This name is logged and sent to the central station for
all the users in the group. The user ID is used to
differentiate which user’s token or card was executed.
When using a D1260 Keypad, User 249
text is used for contact information text
(such as telephone numbers). If a D1260 is
installed on the system, do not use User
249 for user ID information.
3.1.5 Tokens and Cards
The master user assigned the pass code can also be
assigned a token or card by programming the
U###
Mstr Site
and
U### Mstr Crd Data
.
Three more tokens or cards are assigned to the user
group for sub-users using the
U### SU# Site
and
U### SU# C/D
.
3.1.6 Reporting and Logging
Modem Format
must be Yes for the following reports
sent to the central station. Regardless of the reporting
format, they log and print at the local printer as shown
in Figure 4 on page 78. Each sub-user is identified by
the master user’s three-digit number plus an extension
of 0, 1, 2, or 3. These numbers are called Sub-user ID
Codes.
Figure 4 shows all the users for User Group 122 as they
would appear.