D9412GV2/D7412GV2 | Program Entry Guide | 3.0 RADXUSR1/RADXUSR2 EN | 80
Bosch Security Systems | 5/05 | F001U003636B
For more information, refer to the Security Industry
Association (SIA) Access Control 26-bit Wiegand
Reader Interface Standard.
U### Mstr Site
Default: Blank
Selection: 000 = (0) to 254 or Blank (255)
Master User ### Site Data: Enter the first three
decimal numbers on the back of the token or card.
This is the first byte (bits 2 through 9) of data for a 26-
bit Wiegand card. This is called the site number.
Tokens and cards with a site code of 255 are not
compatible with the D9412GV2/D7412GV2 Control
Panels
Converting hexadecimal to decimal: If
your card label contains letters as well as
numbers, the number is hexadecimal.*
Convert the hexadecimal number to decimal
using your calculator. If you cannot convert
in this way, use the reader and the
Add/Chg User? Function to add the tokens
or cards.
Perform the following test to confirm that
you can convert properly:
Use 319EB0 as the hexadecimal number.
On your calculator, press [HEX]. Enter all
the hexadecimal characters into the
calculator. Press [DEC] and your
hexadecimal characters convert to the
following eight digits: 03251888. The site
number is 032. Enter it in U### Mstr Site.
Your card data is 51888. Enter it into
U### Mstr Crd Data.
* A hexadecimal number can contain all
numerals. If the code does not work, try
converting the number from hexadecimal
to decimal.
Always tag your tokens before adding them
to the system so you do not mix them up.
Use the CRD ID ###-# number to index
them.
U### Mstr Crd Data
Default: Blank
Selection: 00000 = (0) to 65534 or Blank (65535)
Master User ### Card Data: Enter the remaining
five decimal numbers on the back of the token or card.
This is the second and third byte (bits 10 through 25)
of data for a 26-bit Wiegand card. This is called the
card data.
You must program
U### Mstr Site
before
programming this prompt.
U### SU1 through SU3 Site
Default: Blank
Selection: 000 = (0) to 254 or Blank (255)
Sub-users one through three site data.
U### SU1 through SU3 C/D
Default: Blank
Selection:
00000 = (0) to 655354 or Blank
(65535)
Card data for sub-users one through three.