D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 16
Bosch Security Systems | 5/05 | F001U003636B
Burglar Reports
Select Yes to send a report when the event occurs.
Table 9: Burglar Reports
Report Selections Report Description
R# Alarm
Yes, No
Burglar Alarm Event
R# Burg
Restore
Yes, No
Non-fire restoral from
trouble, missing, or
supervisory
R# Duress
Yes, No
Duress
R# Missing
Alarm
Yes, No
Missing Alarm point
R# Usr Code
Tmpr
Yes, No
User code tamper
R# Trouble
Rpt
Yes, No
Trouble Event
R# Missing
Trbl
Yes, No
Missing Trouble Event
R# Non Fire
Suprv
Yes, No
Non-fire Supervision
Event
R# Pt Bus Fail
Yes, No
Point bus failure
R# Pt Bus
Rstl
Yes, No
Restoral of point bus
after failure
R# Non Fire
Cncl
Yes, No
Canceled non-fire
alarm
R# Alarm
Restore
Yes, No
Non-fire restoral from
alarm
R# Sup
Missing
Yes, No
Supervisory missing
R# Unverified
Evt
Yes, No
Unverified Events for
Cross Points
R# Unverified
Evt
is not reported when using BFSK
format. Additionally, this event does not produce a
corresponding Restoral event.
R# Unverified Evt is sent when a single
point programmed in Cross Point Group
faults into an alarm condition, then restores
before the Cross Point Time elapses.
R# Unverified Evt encompasses both Fire
and Non-fire points, but is not related to the
A# Verify Time used for smoke detectors.
The 9000GV2 Series control panels log a
Ground Fault Event as Trouble Point 256.
Restoral Reports are not sent if the
control panel resets after a point is
bypassed and then unbypassed. This is
true for both Fire and Non-fire points.
User Reports
Selecting Yes enables a report to be sent when the
event occurs.
Table 10: User Reports
Report Selections Report Description
R# Point
Bypass
Yes, No
Point Bypass Event
R# Forced
Point
Yes, No
Forced Point Event
R# Point
Open
Yes, No
Point Opening Event
R# Point
Close
Yes, No
Point Closing Event
R# Forced
Arm
Yes, No
Point Force Armed
R# Fail To
Open
Yes, No
Fail to Open Event
R# Fail To
Close
Yes, No
Fail to Close Event
R# Ext Clos
Tm
Yes, No
Extend Close Time
Event
R# Opening
Rpt
Yes, No
Opening Events
R# Forced
Close
Yes, No
Point Forced Close
Event
R# Closing
Rpt
Yes, No
Closing Events
R# FC Perim
Inst
Yes, No
Forced Close
Perimeter Instant
Armed Event
R# FC Perim
Delay
Yes, No
Forced Close
Perimeter Delay
Armed Event
R# Perim Inst
Arm
Yes, No
Perimeter Instant
Armed Event
R# Perim
Delay Arm
Yes, No
Perimeter Delay
Armed Event
R# Send User
Text
Yes, No
User text