D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 44
Bosch Security Systems | 5/05 | F001U003636B
D1255 Keypad
After the first valid passcode is entered, the D1255
replaces the scrolling DISARM NOW and the Point Text
display with the SECOND CODE:.display
When the user presses the first digit of the second
code, the display changes to SECOND CODE: *.
SECOND CODE: appears for ten seconds. If no digits
are pressed, the display returns to normal and the area
does not disarm. If a second code is entered, the area
disarms and an Opening report is sent with the User
ID of the first user. If the second code entered is the
same as the first code, is invalid, or does not have
L##
Disarm
authority, the keypad shows NO AUTHORITY
and returns to idle text or entry delay.
D1260 Keypad
In the D1260, after the first valid passcode is entered,
the following message appears for three seconds.
Then the next message appears requesting a second
code.
When the first digit of the second code is pressed, the
following message appears. As each digit is pressed, an
additional asterisk appears.
A# Early Ambush
Default: No
Selection:
Yes or No
Yes Two valid passcodes are required to
disarm the area within the time period
specified in Early Ambush Timer. The
second valid disarm passcode must be
entered within a time limit. Refer to
Early Ambush Timer on page 132.
If the second passcode is not entered
within the time limit, the system
generates a Duress Event based upon
the primary user.
No A single pass code with a valid
authority level can disarm the area.
Use this parameter when disarming an area that is in
the Master Armed state. After the first valid pass code
is entered, the area is disarmed and the keypad
displays the disarmed idle text normally. This function
operates only when you use Passcode Disarm.
If the second valid disarm pass code is entered, the
D1255 Keypad shows CODE 2 VALIDATE and
sounds the Watch Mode tone. Only the Watch Mode
tone appears on the D720 Keypad.
The D1260 Keypad sounds the Watch Mode tone and
the following text appears.